data center humidity solutions

Data Center Humidity Solutions

Data centers are constantly at risk for all sorts of threats, including the environment. Low humidity levels cause dry air, which could spark an electrostatic discharge (ESD). On the other hand, too much humidity causes condensation and the eventual corrosion of vital electronics.

Safeguard your data center by implementing tried and tested humidity solutions from Fogco. We have high-powered humidity systems to keep your data safe and risk-free.

Control My Data Center Humidity

Why Humidity in Data Centers & Server Rooms Matters

Data centers can become compromised due to both low and high humidity. Low humidity levels create a conducive environment for ESD, which can damage your electrical components. 

On the other end of the spectrum, excessive humidity can corrode equipment, causing unexpected downtime and a downturn in revenue. Fogco’s high-powered humidity solutions protect your valuable data. Fogco’s systems help you maintain optimal humidity levels, preventing environmental issues and protecting your hardware.

Learn More
server room humidity

Humidification Challenges in Data Centers & Server Rooms

Data centers and server rooms are challenging environments, but fluctuating humidity comes with its own set of difficulties. If your data center is experiencing changes in humidity, your business could fall prey to:

Equipment Damage

Moisture on motherboards, hard drives, and sockets leads to equipment damage and failure. The American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) recommends a relative humidity (RH) range of 60% and an allowable range of between 20% and 80%RH.

Lost Revenue

Unplanned downtime due to fluctuations in humidity levels can lead to revenue loss. Even worse, these humidity fluctuations can cause permanent harm to your equipment, causing a decrease in earnings and a damaged reputation.

A Tarnished Reputation

As a data center and server room operator, you’re always striving to meet and exceed expectations. Any amount of downtime can negatively impact your reputation, leading to unsatisfied customers.

Let Fogco Help Save Your Reputation

Contact Us
data center humidification

How Fogco Helps Humidify Server Rooms & Data Centers

You might be wondering how humidification maintains humidity levels. It’s all thanks to our atomized water vapor and humidity controllers. Check out some of our best-selling humidification systems ideal for server rooms and data centers:

The Revolution®

The Revolution® is a 2100 CFM high-pressure humidification system able to disperse mist up to 30’. This makes the Revolution® an excellent choice for controlling humidity in large data centers and server rooms.

Shop The Revolution®
Revolution® Humidification Fan
Evolution Humidification Fan Category Image

The Evolution®

If you’re running a smaller server room and need humidification control, the Evolution® is ideal. This misting system covers 1,000 square feet and disperses fog in a uniform distribution line.

Shop The Evolution®

Custom Humidification Systems

sever room humidification

Sometimes it’s best to go custom. Our team of humidification specialists will work with you to put together a completely customized system to meet your data center’s needs.

All Fogco fans require a high-pressure 1,000 PSI pump to achieve ideal performance.

Learn How Fogco Can Help Your Data Center

Talk to a Specialist

Benefits of Using a Humidification System in Server Rooms & Data Centers

Fogco has been a leader in commercial humidification systems. We have over 30 years of experience in product development for cooling, humidification, dust suppression, and even odor control. Over those three decades, we have provided solutions for hundreds of data centers and server rooms just like yours.

Data centers and server rooms rely on Fogco misting systems thanks to benefits like:

Energy Savings

Prevents Electrostatic Discharge

Improves Indoor Air Quality

Controlled & Consistent Humidification

Low Maintenance Costs

And More

Don’t risk the risks. Get your free quote from Fogco.

Data Center & Server Room Humidity FAQ

What are the recommended temperature and humidity levels for a data center?

Data centers should maintain a temperature of between 65 and 75 degrees Fahrenheit with a relative humidity of 60%.

What happens if the humidity level in a data center is too high?

If the humidity level in a data center is too high, your components risk corroding and failing. This is due to condensation build-up as a result of high humidity.

What is the recommended humidity level for server rooms?

Aim for a humidity level between 40% and 55% for server rooms. You can set an alert for when the humidity rises above 70%.

Is low humidity bad for servers?

Yes. Low humidity can cause ESD, which damages sensitive components. Fogco’s temperature and humidity controllers can help manage your humidity and temperature levels.